Specifications
for HEPA air purifier
Model: H-200
Dimensions: 20(hi)
x 15(dp) x 14(wd) in. Comes standard with a handle.
Weight: 31 pounds
Electrical: 115 volts, 60/50 Hz., 120 watts. Actual usage on high speed (with replaceable
filter installed) is approximately 88 watts. This
is less
than a 100 watt light bulb. Motor has automatic reset thermal protection.
(Air delivery approx. 20% less when operated on 50 Hz.)
Filtration
efficiency: Removes up to 99+% of particulates,
based on National Bureau of Standards Dust Spot Test in atmospheric air. This
test includes particles larger, smaller as well as equal to .3 microns. Under
average conditions change HEPA filter once every 12 months.
Particle
size: Effective
down to0.3 and even down to0.1 micron.
Ozone free: Unit
is free
of the health hazards of ozone.
Capacity: Up
to 300 cfm with
a variable speed control. Capacity is based on air movement of motor-blower. Cleans rooms up to 500
sq ft (20
x 25 ft) based
on 8 ft ceiling, which represents 4,000
cu ft. Cleans rooms up to 2,250
sq ft, which based on 8 ft ceiling, which represents 18,000
cu ft at
a reduced effectiveness of 1 air change an hour.
Limited
warranty:24
month warranty on all parts and labor(except
for replacement of expendable HEPA filter)
Tax
deduction:Many
times the law allows medical deduction in event of Physician's prescription.
Vitaire reserves the right to change specifications
without notice. |